EXIDE PLANTE

Type of cell Capacity at27 o C whenDischarging at 10hrsRate to 1.85 v Charging Current TotalMinimum input during initialcharging Weight ofCell +/-5% Approx qty.of acid1.19spgr Overall Dimensions of Containers Overall Cell Height+/- 5mm CorrespondingCell Centres Trickle chargecurrent
Min
Max
 
Length+/- 2mm Breadth +/- 2mm Height +/- 2mm
Starting Rate Finishing Rate Without Acid With Acid
Ah A A Ah Kg Kg Liters Mm Mm Mm Mm
mA
mA
Mm
YAP  
YAP5
16
2
1
6
2.7
4.7
1.7
114
133
212
260
123
10
30
YAP7
24
3
1.5
96
3.5
5.4
1.6
114
133
212
260
123
15
45
YAP9
32
4
2
128
4.3
6.1
1.5
114
133
212
260
123
20
60
YAP11
40
5
2.5
160
5.4
8.8
2.9
190
133
212
260
199
30
90
YAP13
48
6
3
192
6.2
9.5
2.8
190
133
212
260
199
40
120
YAP15
56
7
3.5
224
7
10.2
2.7
190
133
212
260
199
45
135
YAP17
64
8
4
256
7.8
11
2.7
190
133
212
260
199
50
150
YKP
YKP7
75
9
4.5
300
10.5
18.2
6.5
173
203
352
426
217
60
180
YKP9
100
12
6
400
10.5
18.2
6.5
173
203
352
426
217
80
240
YKP11
125
15
7.5
500
15.5
22.4
5.8
173
203
352
426
217
100
300
YKP13
150
18
9
600
18
24.4
5.4
173
203
352
426
217
125
375
YKP15
175
21
10.5
700
19.7
28.7
7.6
210
203
349
423
217
140
420
YKP17
200
24
12
800
22
30.7
7.3
210
203
349
423
217
160
480
YKP19
225
27
13.5
900
24.3
34.9
8.9
248
203
349
423
217
180
540
YKP21
250
30
15
1000
26.7
36.9
8.6
248
203
349
423
217
200
600
YKP23
275
33
16.5
1100
29.1
41.4
10.3
286
203
349
423
217
220
660
YKP25
300
36
18
1200
31.5
43.4
10
286
203
349
423
217
240
720
YKP27
325
39
19.5
1300
36.3
52.6
13.7
362
203
349
423
217
260
780
YKP29
350
42
21
1400
38.5
54.4
13.4
362
203
349
423
217
280
840
YKP31
375
45
22.5
1500
40.8
56.4
13.1
362
203
349
423
217
300
900
YKP33
400
48
24
1600
43.2
58.4
12.8
362
203
349
423
217
320
960
YKP35
425
51
25.5
1700
45.6
60.4
12.5
362
203
349
423
217
340
1020
YHP
YHP11
535
64
32
2140
64.3
96.7
27.2
230
368
597
682
255
300
600
YHP13
645
77
38.5
2580
74.8
105.4
25.7
230
368
597
682
255
360
720
YHP15
750
90
45
3000
93.8
170.6
64.6
433
368
597
682
394
420
840
YHP17
860
103
51.5
3440
104.1
179.5
63.3
433
368
597
682
394
480
960
YHP19
965
166
58
3860
114.4
188.2
62
433
368
597
682
394
550
1100
YHP21
1070
128
64
4280
124.7
196.9
60.7
433
368
597
682
394
600
1200
YHP23
1180
142
71
4720
135
205.7
59.4
433
368
597
682
349
660
1320
YHP25
1285
154
77
5140
145.3
214.4
58.1
433
368
579
682
349
720
1440
YHP27
1395
167
83.5
5580
155.6
220.8
54.8
433
368
597
682
394
780
1560
YHP29
1500
180
90
6000
165.9
229.6
53.5
433
368
597
682
394
850
1700
YHP31
1605
193
96.5
6420
181.7
261
66.6
509
368
597
682
394
900
1800
YHP33
1715
206
103
6860
192
269.6
65.2
509
368
597
682
394
960
1920
YHP35
1820
218
109
7280
202.3
278.3
63.9
509
368
597
682
394
1025
2050
YHP37
1930
232
116
7720
215.9
307.3
76.8
585
368
597
682
394
1100
2200
YHP39
2035
244
122
8140
225.9
315.7
75.6
585
368
597
682
394
1150
2300
YHP41
2140
257
128.5
8560
236.2
324.4
74.1
585
368
597
682
394
1200
2400
YHP43
2250
270
135
9000
246.6
333.1
72.7
585
368
597
682
394
1250
2500
 

Note: The length of a cell is measured at right angles to the plates. The width is measured parallel to the plates.

RECHARGE INSTRUCTIONS
All Plante Cells should normally be floated at a mean float voltage not below 2.18V/Cell as given in Table:4. Should there be any limitation in the charger capacity or load, Plante cells may also be floated at a lower float voltages. In such cases, the battery bank is to be administered an equalization change once in 3 months.
Trickle charging currents should be so adjusted, anywhere between the maximum and minimum allowed levels given in the Table 2, such that individual cells remain fully charged.

Capacity: Ampere-hour output as percentage of 10-hr capacity when discharging in

Hour

1

2

3

4

5

6

7

8

9

10

Final Voltage

1.75

1.78

1.80

1.81

1.82

1.83

1.83

1.84

1.84

1.85

% of 10hr. capacity

60%

76%

83.5%

88.5%

92.3%

95%

96.5%

98%

99%

100%